  • Ammonite 6ZhV charge is housed in polymer casing which consists of a shell and a lid. The shell is provided with a hemispherical hollowness at the bottom. The lid is fitted with a fixer for an initiation device to be attached to the charge.

 

Main Characteristics

 of А-6ZhV Hollow Charges

Parameters

Value

Mass of explosive per charge, g

1600±150

Dimensions, mm:

height (Н)

diameter (D)

radius of hollow (R)

 

115+6

190+2

45+1

Gas volume , g/kg

895

Temperature of explosion, 0С

2960

TNT equivalent

1,03

Completeness of detonation

Complete

Explosion heat, kcal/kg (kJ/kg)

4312 (1030)

Velocity of detonation, km/s, not less than

3,6-4,8

Critical diameter of detonation of unconfined charge, mm

10-13

Oxygen balance, %

-0,53

 

А-6ZhV Hollow Charges

  • According to transportation and storage hazard classification, the explosive is assigned to Class 1, Division 1.1 and Compatibility group D. UN number is 0059.

А-6ZhV Hollow Charges

  • Supplies: in corrugated cardboard boxes. Nominal explosives net weight per box is not over 25 kg.
  • A-6ZhV Hollow Charges can be delivered by railway, maritime, river and departmental motor transport.

 

Hollow mudcap water gel charges

 Hollow Charge – 1000 TU U 3.50-14310112-120-98

 

Hollow charge – 1000

  • Suitable for blasting fragmentation of boulders in open cast and underground mining, in mines and pits not endangered by firedamp and combustible dust; as well as for crushing of pig iron and steel scrap in iron and steelmaking, at ambient air temperature of -10 0С to +50 0С.

Hollow charge - 1000

  • Assigned to Class C explosives (by application environment), it is initiated by electric detonator, blasting cap and detonating cord.

Hollow charge - 1000

  • The charge is filled with water gel explosive (Gelex 650), which is fire dangerous and explosion hazardous material.

Hollow charge - 1000

  • Without boosters, normally containing highly sensitive explosives, these charges are safer to handle than cast TNT charges coming with boosters.

 

Main characteristics of Hollow Charge – 1000

Parameters

Value

Explosion heat, kcal/kg

1152

Explosive temperature, degree С

4004

Gas volume, l/kg

784

Quantity of poison gases on conventional carbon oxide basis, l/kg

29,85

Critical diameter of detonation of open charge, mm

23

TNT equivalent through explosion heat

1,15

Velocity of detonation, km/s, not less than

4,5-5,0

Basic dimensions, mm

Height (Н)

98+6

Diameter (D)

150+2

Radius of hollow (R)

35+1

Completeness of detonation

complete

Hazard Class

Class 1

Hazard Division

Division 1,1

Compatibility Group

D

UN number

UN - 0241

 

Hollow charges – 1000

  • Supplies: in corrugated cardboard boxes or fiberboard boxes. Nominal explosives net weight per corrugated cardboard box is not above 25 kg and per fiberboard box is not above 40 kg.
  • Hollow Charges – 1000 are delivered by railway and departmental motor transport.

 

Hollow Charge – 2000 TU U 3.50-14310112-120-98

 

Hollow charge - 2000

  • Suitable for blasting fragmentation of boulders in open cast and underground mining, in mines and pits not endangered by firedamp and combustible dust; as well as for crushing of pig iron and steel scrap in iron and steelmaking, at ambient air temperature of -10 0С to +50 0С.

Hollow charge - 2000

  • Assigned to Class C explosives (by application environment), it is initiated by electric detonator, blasting cap and detonating cord.

Hollow charge - 2000

  • The charge is filled with water gel explosive (Gelex 650), which is fire dangerous and explosion hazardous material.

Hollow charge - 2000

  • Without boosters, normally containing highly sensitive explosives, these charges are safer to handle than cast TNT charges coming with boosters.

 

Main characteristics of Hollow Charge – 2000

Parameters

Value

Explosion heat, kcal/kg

1152

Explosive temperature, degree С

4004

Gas volume, l/kg

784

Quantity of poison gases on conventional carbon oxide basis, l/kg

29,85

Critical diameter of detonation of open charge, mm

23

TNT equivalent through explosion heat

1,15

Velocity of detonation, km/s, not less than

4,5-5,0

Basic dimensions, mm

Height (Н)

115+6

Diameter (D)

190+2

Radius of hollow (R)

45+1

Completeness of detonation

complete

Hazard Class

Class 1

Hazard Division

Division 1,1

Compatibility Group

D

UN number

UN - 0241

 

Hollow charges – 2000

  • Supplies: in corrugated cardboard boxes or fiberboard boxes. Nominal explosives net weight per corrugated cardboard box is not above 25 kg and per fiberboard box is not above 40 kg.
  • Hollow Charges – 2000 are delivered by railway and departmental motor transport.

 

Hollow Charge – 4000 TU U 3.50-14310112-120-98

 

Hollow charge - 4000

  • Suitable for blasting fragmentation of boulders in open cast and underground mining, in mines and pits not endangered by firedamp and combustible dust; as well as for crushing of pig iron and steel scrap in iron and steelmaking, at ambient air temperature of -10 0С to +50 0С.

Hollow charge - 4000

  • Assigned to Class C explosives (by application environment), it is initiated by electric detonator, blasting cap and detonating cord.

Hollow charge - 4000

  • The charge is filled with water gel explosive (Gelex 650), which is fire dangerous and explosion hazardous material.

Hollow charge - 4000

  • Without boosters, normally containing highly sensitive explosives, these charges are safer to handle than cast TNT charges coming with boosters.

 

Main characteristics of Hollow charge – 4000

 

Parameters

Values

Explosion heat, kcal/kg

1152

Explosive temperature, degree С

4004

Gas volume, l/kg

784

Quantity of poison gases on conventional carbon oxide basis, l/kg

29,85

Critical diameter of detonation of open charge, mm

23

TNT equivalent through explosion heat

1,15

Velocity of detonation, km/s, not less than

4,5-5,0

Basic dimensions, mm

Height (Н)

115+6

Diameter (D)

190+2

Radius of hollow (R)

45+1

Completeness of detonation

complete

Hazard Class

Class 1

Hazard Division

Division 1,1

Compatibility Group

D

UN number

UN - 0241

Hollow charges – 4000

  • Supplies: in corrugated cardboard boxes or fiberboard boxes. Nominal explosives net weight per corrugated cardboard box is not above 25 kg and per fiberboard box is not above 40 kg.
  • Hollow Charges – 4000 are delivered by railway and departmental motor transport.

SOME HISTORY FACTS





10,000

Tonnes of iron
Shot at Siege of Sebastopol during Crimean War





144,000

Revolutions per minute
Does a bullet fired from Lee Enfield rifle, as used in both world wars





2,000

Women
The Nizam of Hyderabad raised in 1975 for his war against the Marathas





130,000

Meters
Is an effective range of Big Bertha, the World War I howitzer


Interested in partnership opportunities? Contact us

Contact Information

ABOUT SPETS TECHNO EXPORT

State Foreign Trade Enterprise “SpetsTechnoExport” is a fully state-run entity incorporated by the Government of Ukraine in 1998 for export-import activities at foreign armaments markets.

HEAD OFFICE

7, Stepana Bandery Avenue
Kyiv, 04073, Ukraine
tel: +380 44 5685070
fax: +380 44 5685068

LIAISON OFFICE

B-5/147 Safdarjung
110057, New Delhi
tel: +91 11 26153792
fax: +91 11 26153830

OUR NEWSLETTER

Subscribe to automatically receive STE press releases.


STE, Спецтехноекспорт, Спецтехноэкспорт

Разработка сайтов - PHAR